{"id":66,"date":"2025-09-03T17:15:58","date_gmt":"2025-09-03T09:15:58","guid":{"rendered":"https:\/\/tavnu.com\/?post_type=product&#038;p=66"},"modified":"2025-09-27T12:59:29","modified_gmt":"2025-09-27T04:59:29","slug":"atp-fluorescence-detector","status":"publish","type":"product","link":"https:\/\/tavnu.com\/?product=atp-fluorescence-detector","title":{"rendered":"ATP Fluorescence Detector"},"content":{"rendered":"<div class=\"video video-fit mb\" style=\"padding-top:56.25%;\"><p><iframe loading=\"lazy\" title=\"ATP Fluorescence Detector Display\" width=\"1020\" height=\"574\" src=\"https:\/\/www.youtube.com\/embed\/n5mvsuSPlC0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<\/div>\n<table style=\"height: 475px\" width=\"623\">\n<tbody>\n<tr>\n<td>Weight<\/td>\n<td>1 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>7.40 \u00d7 3.03 \u00d7 1.46 inches<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1 \u00d7 10-18 mol<\/td>\n<\/tr>\n<tr>\n<td>Detection range<\/td>\n<td>0-999999 RLUs<\/td>\n<\/tr>\n<tr>\n<td>Coliform bacteria<\/td>\n<td>1-106 cfu<\/td>\n<\/tr>\n<tr>\n<td>Detection time<\/td>\n<td>15 seconds<\/td>\n<\/tr>\n<tr>\n<td>Detection interference<\/td>\n<td>\u00b15\u00b0C or \u00b15 RLUs<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature range<\/td>\n<td>5\u00b0C to 40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Operating humidity range<\/td>\n<td>\u00a020-85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Detection mode<\/td>\n<td>RLU, coliform bacteria screening<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Display<\/td>\n<td>3.5-inch high-precision graphic touch screen<\/td>\n<\/tr>\n<tr>\n<td>Processor<\/td>\n<td>32-bit high-speed data processing chip<\/td>\n<\/tr>\n<tr>\n<td>USB port<\/td>\n<td>Equipped with a miniUSB port for uploading results to a PC<\/td>\n<\/tr>\n<tr>\n<td>Charging method<\/td>\n<td>Rechargeable lithium battery, no battery replacement required<\/td>\n<\/tr>\n<tr>\n<td>Swab<\/td>\n<td>solid swab, water swab<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Product Features<\/h2>\n<div class=\"row\"  id=\"row-536923818\">\n\n\t<div id=\"col-257187211\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1636140070\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"416\" height=\"446\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-15-seconds-rapid-detection-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-15-seconds-rapid-detection-1.webp 416w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-15-seconds-rapid-detection-1-280x300.webp 280w\" sizes=\"auto, (max-width: 416px) 100vw, 416px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1636140070 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-382383226\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>15-second Rapid Detection<\/h3>\n<p>The 15-second rapid testing function eliminates the hours of waiting in traditional laboratories and provides results within 15 seconds of on-site sampling. Whether it&#8217;s a regulatory surprise inspection, real-time enterprise quality control, or hospital verification of disinfection effectiveness, it can instantly grasp the hygiene status and quickly identify potential hazards, improving testing efficiency while avoiding delays in health risk management.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-356157139\">\n\n\t<div id=\"col-98191539\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_247713063\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1655\" height=\"1122\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1.webp 1655w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1-600x407.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1-300x203.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1-1024x694.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1-768x521.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Freely-set-upper-and-lower-values-1-1536x1041.webp 1536w\" sizes=\"auto, (max-width: 1655px) 100vw, 1655px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_247713063 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-998844539\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Freely Set Upper and Lower Values<\/h3>\n<p>The user-defined upper and lower thresholds allow for custom microbial residue acceptance thresholds based on hygiene standards for various scenarios, such as tableware disinfection and workshop cleanliness. The device provides prompt notifications when test results exceed or fall below the upper or lower limit, meeting the diverse needs of various industries while making hygiene assessments more intuitive and efficient, and reducing human interpretation errors.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1675869991\">\n\n\t<div id=\"col-418632256\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1319732535\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"601\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Highly-Sensitive-Imported-Photoelectric-Sensor.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Highly-Sensitive-Imported-Photoelectric-Sensor.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Highly-Sensitive-Imported-Photoelectric-Sensor-600x352.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Highly-Sensitive-Imported-Photoelectric-Sensor-300x176.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Highly-Sensitive-Imported-Photoelectric-Sensor-768x451.webp 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1319732535 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1869550303\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>\u00a0Highly Sensitive Imported Photoelectric Sensor<\/h3>\n<p>Equipped with a highly sensitive imported photoelectric sensor, it can accurately capture weak fluorescent signals during detection and accurately identify even extremely low ATP levels in samples, effectively avoiding missed detections or misjudgments. At the same time, it can ensure the stability of signal conversion, provide reliable support for subsequent data processing, and further improve the accuracy of test results.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-343536696\">\n\n\t<div id=\"col-972136976\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_257245130\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"426\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-test-result-qualified.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-test-result-qualified.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-test-result-qualified-300x213.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_257245130 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1834897992\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Automatic Result Judgment and Pass Rate Statistics Function<\/h3>\n<p>Automatic pass\/fail judgment and pass rate statistics eliminate the need for manual comparison and calculation of test data one by one. It can quickly output the result of whether a single sample is qualified or not, and automatically summarize all data and calculate the pass rate. This not only reduces errors in manual recording and calculation, but also significantly saves time in collating results after batch testing, making test result judgment more efficient and statistics more accurate.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1679572423\">\n\n\t<div id=\"col-1019715868\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_795416013\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"630\" height=\"516\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-12-hours-continuous-testing-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-12-hours-continuous-testing-1.webp 630w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-12-hours-continuous-testing-1-600x491.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-12-hours-continuous-testing-1-300x246.webp 300w\" sizes=\"auto, (max-width: 630px) 100vw, 630px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_795416013 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2056382446\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>12 Hours Continuous Testing<\/h3>\n<p>The 12-hour continuous detection capability makes it suitable for batch scenarios such as food workshop random inspections, hospital disinfection inspections, and centralized regulatory inspections. It does not require frequent shutdowns for charging or restarts, and can output results stably, reducing efficiency losses and ensuring the continuous implementation of large-scale health screenings.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1685142973\">\n\n\t<div id=\"col-776125551\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_556414329\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"390\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-High-definition-screen.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-High-definition-screen.webp 386w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-High-definition-screen-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-High-definition-screen-297x300.webp 297w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_556414329 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-556829291\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>3.5-inch High-definition Touch Screen<\/h3>\n<p>The 3.5-inch high-definition touchscreen not only clearly displays test parameters, result data, and operational instructions, but also offers a more responsive touch interface. Whether quickly switching test modes, customizing thresholds, or retrieving historical test records, these features can be easily mastered by medical staff, supervisors, and even company personnel, reducing operational barriers and making the testing process more convenient and efficient.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1900904012\">\n\n\t<div id=\"col-1598901742\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_109392476\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"396\" height=\"374\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-30-second-power-on-self-test-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-30-second-power-on-self-test-1.webp 396w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-30-second-power-on-self-test-1-300x283.webp 300w\" sizes=\"auto, (max-width: 396px) 100vw, 396px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_109392476 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2013824885\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h2>30-second Power-on Self-test<\/h2>\n<p>The 30-second power-on self-test function, with the help of a built-in self-calibration light source, quickly verifies the instrument&#8217;s core components and system status, preventing distorted test results caused by equipment failure. This ensures that the equipment is in normal working condition before testing, reduces the need for subsequent repeated testing, and effectively improves test reliability.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2143287021\">\n\n\t<div id=\"col-1073841108\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_913497964\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2303\" height=\"1525\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable.webp 2303w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-300x199.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-1024x678.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-768x509.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-1536x1017.webp 1536w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-2048x1356.webp 2048w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Swab-Cannula-Washable-600x397.webp 600w\" sizes=\"auto, (max-width: 2303px) 100vw, 2303px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_913497964 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-881436556\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>The swab cannula can be pulled out for cleaning<\/h3>\n<p>The swab cannula adopts a flexible plug-in design and can be pulled out directly for cleaning. After each test, the inner wall residue can be quickly cleaned to avoid cross-contamination of samples to ensure accurate results. It can also be cleaned regularly for long-term use, which not only improves the user experience but also extends the overall life of the cannula and instrument.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1808466573\">\n\n\t<div id=\"col-2059324090\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_784584159\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1500\" height=\"992\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip.webp 1500w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip-600x397.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip-300x198.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip-1024x677.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-chip-768x508.webp 768w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_784584159 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1026976032\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>32-bit High-speed Data Processing Chip<\/h3>\n<p>Equipped with a 32-bit high-speed data processing chip, it can quickly calculate and analyze fluorescence signal data. It can not only perform rapid detection in 15 seconds, but also efficiently respond to historical record queries, threshold settings and other operations without data lag issues, which not only improves detection efficiency but also ensures smooth equipment operation.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1179641958\">\n\n\t<div id=\"col-1951437573\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_103367537\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"679\" height=\"753\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-size-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-size-1.webp 679w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-size-1-600x665.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-size-1-271x300.webp 271w\" sizes=\"auto, (max-width: 679px) 100vw, 679px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_103367537 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1232492053\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Small Size and Easy to Carry<\/h3>\n<p>The ATP fluorescence detector is compact and lightweight, making it easy to hold in one hand or put into a portable tool bag without taking up too much space. It can also easily adapt to scenarios such as portable boxes for outdoor spot checks and narrow workbenches in workshops, without the need for additional large storage areas, greatly improving its portability and flexibility during mobile testing.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h2>Product Detail<\/h2>\n<div class=\"row\"  id=\"row-137812441\">\n\n\t<div id=\"col-158825049\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1671806189\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2.webp 1600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-600x600.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-1024x1024.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-150x150.webp 150w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-768x768.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-2-1536x1536.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1671806189 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-349430683\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Upgrade Swabs<\/h3>\n<p>The matching upgraded swab not only has better adsorption capacity and sample release efficiency, can fully collect surface microbial residues to reduce sampling errors, but also has better material compatibility, can adapt to instrument processes and shorten reaction time, which not only improves detection accuracy, but also provides efficient support for batch testing scenarios.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1259894821\">\n\n\t<div id=\"col-2031446791\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1163170464\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"652\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-120\u00b0top-cover-opening-and-closing-design.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-120\u00b0top-cover-opening-and-closing-design.webp 916w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-120\u00b0top-cover-opening-and-closing-design-600x427.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-120\u00b0top-cover-opening-and-closing-design-300x214.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-120\u00b0top-cover-opening-and-closing-design-768x547.webp 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1163170464 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1804990626\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>120\u00b0 Top Cover Opening and Closing Design<\/h3>\n<p>The 120-degree top cover opening and closing design provides more ample operating space, allowing users to quickly remove and place swab tubes without having to deliberately control the opening and closing angle. When batch testing is frequently performed, it can reduce hand obstruction and operational obstacles, improving ease of use. It can also avoid component wear caused by too small an opening and closing angle, thereby extending the service life of the top cover.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1486838875\">\n\n\t<div id=\"col-2053775527\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1687182996\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1428\" height=\"444\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port.webp 1428w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port-600x187.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port-300x93.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port-1024x318.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-miniUSB-Port-768x239.webp 768w\" sizes=\"auto, (max-width: 1428px) 100vw, 1428px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1687182996 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-833391488\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Mini USB Port<\/h3>\n<p>The miniUSB interface allows for convenient connection to computers, chargers, and other devices. It not only allows for quick export of test data for statistical analysis or report retention, but also allows for charging the device at any time, meeting the data transmission and battery life requirements of on-site testing. It&#8217;s simple to operate and compatible with common external devices, enhancing flexibility.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-155637908\">\n\n\t<div id=\"col-1609302106\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1123111055\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"806\" height=\"278\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive.webp 806w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-600x207.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-300x103.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-768x265.webp 768w\" sizes=\"auto, (max-width: 806px) 100vw, 806px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1123111055 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-826009378\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>USB Flash Drive<\/h3>\n<p>A USB flash drive (including computer software) can be directly connected to the device to export data, eliminating the need for additional transfer tools. The exported test data can be quickly organized, analyzed, or used to generate reports using the computer software in the USB flash drive. The software also facilitates subsequent updates and maintenance, simplifying the data processing process and facilitating the archiving and management of test results.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1366632726\">\n\n\t<div id=\"col-1663314872\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_365039839\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"746\" height=\"548\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Large-Capacity-Lithium-Battery-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Large-Capacity-Lithium-Battery-1.webp 746w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Large-Capacity-Lithium-Battery-1-300x220.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Large-Capacity-Lithium-Battery-1-600x441.webp 600w\" sizes=\"auto, (max-width: 746px) 100vw, 746px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_365039839 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1229672382\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Large-capacity Lithium Battery<\/h3>\n<p>The built-in high-performance lithium battery (3AH) provides continuous operation for more than 12 hours and a standby time of more than 300 hours, providing long-lasting battery life without the need for frequent external power supply. Whether it is outdoor water quality sampling, mobile market supervision, or multi-point testing in the workshop, it can ensure the continuous operation of the equipment and avoid interruptions due to insufficient power, effectively improving the flexibility of use and detection efficiency in mobile scenarios.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-244326120\">\n\n\t<div id=\"col-294824397\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1090943992\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"522\" height=\"468\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box.webp 522w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-300x269.webp 300w\" sizes=\"auto, (max-width: 522px) 100vw, 522px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1090943992 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-699396551\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Aluminum Box<\/h3>\n<p>The equipped aluminum box is both sturdy and lightweight. It can not only protect the instrument from collision, extrusion and dust during transportation or carrying, and protect the body and accessories (such as swabs and USB flash drives) intact, but also can neatly store various components to avoid loss or clutter. It is especially suitable for mobile scenarios such as outdoor spot checks and cross-regional supervision, providing guarantees for the portable use and long-term maintenance of the equipment.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h2>Application Scenarios<\/h2>\n<div class=\"row\"  id=\"row-742989922\">\n\n\t<div id=\"col-615465744\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_446725311\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-water-quality.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-water-quality.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-water-quality-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_446725311 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-464419335\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Water Quality Testing<\/h3>\n<p>The scope of application covers drinking water, secondary water supply, industrial water, etc. It can quickly detect microorganisms and biological residues in water bodies and determine whether the water quality is polluted without waiting for laboratory testing. It provides a basis for water quality safety control in a timely manner to ensure water hygiene.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-142678584\">\n\n\t<div id=\"col-1262451002\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1811063889\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-tableware.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-tableware.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-tableware-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1811063889 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-154768059\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Tableware Surfaces<\/h3>\n<p>Applicable to plates, bowls, chopsticks, etc. in restaurants, canteens and other places. It can quickly screen bacterial residues on the surface of tableware, determine whether cleaning and disinfection standards have been met, avoid cross contamination, and provide instant reference for restaurant hygiene control.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-345011934\">\n\n\t<div id=\"col-560816497\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1923035977\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Market-supervision.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Market-supervision.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Market-supervision-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1923035977 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-649892361\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Market Supervision<\/h3>\n<p>It is suitable for on-site spot checks by supervisors in supermarkets, farmers&#8217; markets, and catering establishments. It can detect the sanitation of food, utensils, and environmental surfaces. The results are available in 15 seconds, improving supervision efficiency and enabling timely detection and disposal of health hazards.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-130071776\">\n\n\t<div id=\"col-1749714922\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_196358526\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-canteen.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-canteen.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-canteen-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_196358526 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-552699224\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Food Safety<\/h3>\n<p>Applicable to food raw materials, semi-finished products in the processing process and the surface of finished products, it can quickly detect microbial residues, timely check risks such as raw material contamination and processing contamination, prevent unqualified food from entering the market, and protect food consumption safety.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-80983021\">\n\n\t<div id=\"col-1626187927\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_657648404\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Food-Processing-Plants.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Food-Processing-Plants.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Food-Processing-Plants-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_657648404 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1887512049\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Production Workshops<\/h3>\n<p>Applicable to key areas such as equipment surfaces, operating tables, and floors in workshops in the food, pharmaceutical, and electronics industries. It monitors environmental cleanliness in real time to prevent microbial contamination from affecting product quality and ensure hygiene compliance in the production process.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1464226627\">\n\n\t<div id=\"col-1448540201\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_440948445\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Hospital.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Hospital.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Hospital-300x200.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_440948445 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2069207752\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Hospital Disinfection<\/h3>\n<p>Applicable to areas such as ward bed units, surgical instruments, diagnostic equipment, corridor handrails, etc., to verify the residual microorganisms after disinfection, determine whether medical and health standards are met, and reduce the risk of cross-infection between doctors and patients.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h3>Other application industries<\/h3>\n<div class=\"accordion\">\n\t<div id=\"accordion-352057757\" class=\"accordion-item\">\n\t\t<a id=\"accordion-352057757-label\" class=\"accordion-title plain\" href=\"#accordion-item-industrial-water-treatment-industry\" aria-expanded=\"false\" aria-controls=\"accordion-352057757-content\">\n\t\t\t<button class=\"toggle\" aria-label=\"Toggle\"><i class=\"icon-angle-down\" aria-hidden=\"true\"><\/i><\/button>\n\t\t\t<span>Industrial water treatment industry<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-352057757-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-352057757-label\">\n\t\t\t\n<p>The instrument is used for microbial monitoring in circulating water and sewage treatment systems, quickly detecting microbial residues, warning of biosludge and water quality deterioration risks, preventing pipe blockage and equipment corrosion, ensuring system stability and reducing the use of chemicals.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-1570625339\" class=\"accordion-item\">\n\t\t<a id=\"accordion-1570625339-label\" class=\"accordion-title plain\" href=\"#accordion-item-customs-entry-and-exit-quarantine\" aria-expanded=\"false\" aria-controls=\"accordion-1570625339-content\">\n\t\t\t<button class=\"toggle\" aria-label=\"Toggle\"><i class=\"icon-angle-down\" aria-hidden=\"true\"><\/i><\/button>\n\t\t\t<span>Customs entry and exit quarantine<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-1570625339-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-1570625339-label\">\n\t\t\t\n<p>The instrument is used for on-site random inspection of food, agricultural products and other inbound and outbound goods, quickly screening for microbial contamination, determining the risk of spoilage or harmful microorganisms, shortening quarantine time, improving customs clearance efficiency, and safeguarding national security.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n\t<div id=\"accordion-3817363644\" class=\"accordion-item\">\n\t\t<a id=\"accordion-3817363644-label\" class=\"accordion-title plain\" href=\"#accordion-item-pharmaceutical-industry\" aria-expanded=\"false\" aria-controls=\"accordion-3817363644-content\">\n\t\t\t<button class=\"toggle\" aria-label=\"Toggle\"><i class=\"icon-angle-down\" aria-hidden=\"true\"><\/i><\/button>\n\t\t\t<span>pharmaceutical industry<\/span>\n\t\t<\/a>\n\t\t<div id=\"accordion-3817363644-content\" class=\"accordion-inner\" aria-labelledby=\"accordion-3817363644-label\">\n\t\t\t\n<p>The instrument is used for microbial testing of clean area environments in production workshops and pharmaceutical raw materials and auxiliary materials. It can quickly verify the effectiveness of cleaning and disinfection, identify potential contamination hazards, avoid excessive microbial counts in pharmaceuticals, ensure compliance with GMP regulations, and reduce production risks.<\/p>\n\t\t<\/div>\n\t<\/div>\n\t\n<\/div>\n<h2>Industry Standard Thresholds<\/h2>\n<table>\n<tbody>\n<tr>\n<td>Application Scenarios<\/td>\n<td>Eligible scope<\/td>\n<td>Warning value<\/td>\n<\/tr>\n<tr>\n<td>Water Testing \u2013 Drinking Water<\/td>\n<td>\u226410 RLU<\/td>\n<td>&gt;10 RLU and \u226450 RLU<\/td>\n<\/tr>\n<tr>\n<td>Tableware surfaces \u2013 clean knives, cutting boards, cutlery, etc.<\/td>\n<td>\uff1c30 RLU<\/td>\n<td>30 RLU to 100 RLU<\/td>\n<\/tr>\n<tr>\n<td>Market surveillance \u2013 food contact surfaces<\/td>\n<td>\u226430 RLU<\/td>\n<td>30 RLU to 100 RLU<\/td>\n<\/tr>\n<tr>\n<td>Workshop environment \u2013 food processing workshop equipment surface<\/td>\n<td>\u226430 RLU<\/td>\n<td>30 RLU to 100 RLU<\/td>\n<\/tr>\n<tr>\n<td>Food Safety Testing \u2013 Surface of Cooked Meat Products<\/td>\n<td>\u226430 RLU<\/td>\n<td>30 RLU to 100 RLU<\/td>\n<\/tr>\n<tr>\n<td>Hospital sanitation and disinfection \u2013 surgical instruments<\/td>\n<td>\u2264150 RLU<\/td>\n<td>150 RLU to 300 RLU<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 130%\"><strong>Note:<\/strong><\/span>In actual application, it should be flexibly adjusted according to specific circumstances, industry norms and relevant standards.<\/p>\n<h2>Limit Value Setting<\/h2>\n<p>1. Recommended general limit values. If time is of the essence, an ATP hygiene monitoring program should be established immediately. These limit values \u200b\u200bare determined based on the specific instrumentation and plate counts of the sample being tested.<br \/>\n2. Establishing custom limit values:<br \/>\n\u2460 Specimens should be obtained from surfaces that appear clean to the naked eye after each deep cleaning.<br \/>\n\u2461 Repeat the test five times and compile the results.<\/p>\n<h3>Example 1<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Serial number<\/td>\n<td>Detection value RLU<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">1<\/td>\n<td style=\"text-align: left\">26<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>19<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>24<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"row\"  id=\"row-1732151066\">\n\n\t<div id=\"col-40840388\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1560667797\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"626\" height=\"226\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Standard-Deviation-Formula.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Standard-Deviation-Formula.webp 626w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Standard-Deviation-Formula-300x108.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Standard-Deviation-Formula-600x217.webp 600w\" sizes=\"auto, (max-width: 626px) 100vw, 626px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1560667797 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-615392187\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>The above are the test results for a specific surface after five cleanings.<br \/>\n\u2460 First, calculate the average of these RLU values, which is (26 + 29 + 32 + 19 + 24) \/ 5 = 26.<br \/>\n\u2461 Then calculate the standard deviation (SD) of the data set. The calculation method of standard deviation (SD) is as shown on the left.<br \/>\n\u2462The standard deviation is 4.95 (rounded to approximately 5).<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<p>Standard deviation (s.d) is a measure of the dispersion of data distribution, which is used to measure the degree to which data values \u200b\u200bdeviate from the arithmetic mean.Set the limit values \u200b\u200bas follows:<\/p>\n<table>\n<tbody>\n<tr>\n<td>Settlement formula<\/td>\n<td>Result<\/td>\n<\/tr>\n<tr>\n<td>Pass &lt; Average<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td>Unqualified \u2265 average value + 3 times the standard value deviation<\/td>\n<td>26+5\u00d73<\/td>\n<\/tr>\n<tr>\n<td>Be wary of deviations \u2265 average value &lt; 3 times the standard value<\/td>\n<td>26-41<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><span style=\"font-size: 130%\">Note:<\/span><\/strong> If the user already has a control point total colony count standard plate count standard, the ATP test results can be used as a reference. However, please note that ATP comes from microorganisms or organic residues, so it can only be said that ATP levels are closely correlated with the number of microorganisms. There is not a complete one-to-one correspondence between ATP testing and plate count results, but there is a close correlation.<\/p>\n<h2>Device Operation Page<\/h2>\n<div class=\"row\"  id=\"row-217334514\">\n\n\t<div id=\"col-583417170\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1673888438\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Home-page-interface.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Home-page-interface.webp 800w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Home-page-interface-600x450.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Home-page-interface-300x225.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Home-page-interface-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1673888438 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1207887374\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Front Page<\/h3>\n<p>Press the button on the left side of the instrument, turn on the instrument and calibrate for 30 seconds before the home page appears.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-2128932218\">\n\n\t<div id=\"col-928924121\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_979543235\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-setting.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-setting.webp 800w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-setting-600x450.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-setting-300x225.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-setting-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_979543235 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2024440345\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Set up<\/h3>\n<p>The setting page of the ATP fluorescence detector supports the adjustment of upper and lower limits, time and other parameters. It can adapt to the detection standards of different scenarios, meet personalized needs, make the result judgment more in line with reality, and improve the flexibility and applicability of the detection.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1822914272\">\n\n\t<div id=\"col-1476766425\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1573602776\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-History.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-History.webp 800w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-History-600x450.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-History-300x225.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-History-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1573602776 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1677784391\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Historical Test Data<\/h3>\n<p>The historical detection record function of the ATP fluorescence detector can easily trace past detection data, facilitate comparison of changes in hygiene conditions at different time periods, help analyze the effects of cleaning and disinfection, and troubleshoot potential problems. At the same time, it provides a reliable historical basis for hygiene management and supervision, and improves work efficiency.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h2>Detection Principle of ATP Fluorescence Detector<\/h2>\n<p>The core mechanism of ATP fluorescence detection is the luciferase-luciferin system, based on the principle of firefly luminescence. All living biological cells (including microorganisms) and residual organic matter contain the energy molecule ATP. During the test, ATP in the sample reacts with luciferase and luciferin in specialized reagents under specific conditions, releasing energy and stimulating fluorescence. The intensity of the light signal is proportional to the ATP content. The instrument converts the light signal into relative light units (RLUs), which directly reflect the amount of ATP in the sample. Because ATP content is positively correlated with the number of microorganisms and residual organic matter, the RLU value can be used to quickly and indirectly determine the degree of contamination. Compared to traditional microbial culture methods, this test eliminates the need to wait for bacterial proliferation and provides instant results, enabling rapid assessment of sanitary conditions.<\/p>\n<div class=\"video video-fit mb\" style=\"padding-top:56.25%;\"><p><iframe loading=\"lazy\" title=\"ATP Fluorescence Detector Detection\" width=\"563\" height=\"1000\" src=\"https:\/\/www.youtube.com\/embed\/h7YT8ITzBhM?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<\/div>\n<h2>Swabs<\/h2>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1973667845\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"800\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1.webp 1000w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1-600x480.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1-300x240.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1-768x614.webp 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1973667845 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<h3>Moistened All-in-one Collection Swab<\/h3>\n<p>The ATP bioluminescence detection swab is a dedicated integrated device that needs to be used with an ATP fluorescence detector. It integrates sample collection, reaction and rapid detection functions. It uses advanced liquid stable reagents, which is not only more convenient to use, but also can bring more accurate test results, and the luminescence signal lasts longer and has better repeatability. Structurally, the swab is mainly composed of three parts: a sealing cap, a sealing tube and a cotton swab.There are two types of test swabs: solid surface swabs and water sample swabs.<\/p>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1489192636\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1830\" height=\"1340\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs.webp 1830w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs-600x439.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs-300x220.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs-1024x750.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs-768x562.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Solid-surface-swabs-1536x1125.webp 1536w\" sizes=\"auto, (max-width: 1830px) 100vw, 1830px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1489192636 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<h3>Solid Surface Swabs<\/h3>\n<p>1.Remove the swab from the refrigerator and let it cool to room temperature for 20-30 minutes, or warm the top of the swab capsule with your palm for 5 minutes to activate it.<br \/>\n2. Remove the swab from the cannula, pinch the connector firmly, and thoroughly wipe the surface at a 45\u00b0 angle. (Figure 1)<br \/>\n3.Insert the collector back into the cannula and tighten. (Figure 2)<br \/>\n4. Pinch the connector with one hand and the top of the capsule with the other, bending it back and forth until the valve snaps off. (Figure 3)<br \/>\n5. Squeeze the swab tip three times to remove all liquid. (Figure 4)<br \/>\n6. Hold the swab tip firmly and shake it downward five times, left and right. Immediately insert it into the instrument for testing. (Figure 5)<\/p>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_285059782\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1200\" height=\"800\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab.webp 1200w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab-600x400.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab-300x200.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab-1024x683.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Water-Swab-768x512.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_285059782 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<h3>Water Swab<\/h3>\n<p>1. Allow the refrigerated or frozen swab to rest at room temperature for approximately 25 minutes (refer to surface swab procedures).<br \/>\n2. Gently unscrew the lower tube, taking care not to allow the swab to touch other objects and to avoid prolonged exposure to air.<br \/>\n3. Completely immerse the swab in the test solution for 1-2 seconds, then quickly remove it and insert the sealing tube.<br \/>\n4. Break off the sealing rod and squeeze to allow the test solution to flow to the cotton tip. Shake the bottom of the swab for approximately 5 seconds.<br \/>\n5. Quickly place the swab in the ATP fluorescence detector, press the test button, and read the result after 15 seconds.<\/p>\n<h2>ATP Bacteria Detection Steps<\/h2>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_2001320835\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1750\" height=\"426\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1.webp 1750w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1-600x146.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1-300x73.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1-1024x249.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1-768x187.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-1-1536x374.webp 1536w\" sizes=\"auto, (max-width: 1750px) 100vw, 1750px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_2001320835 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<p>1. Turn on the device and click \u201cDetection\u201d ,The instrument will prompt \u201cInsert swab\u201d to enter the test interface.<br \/>\n2. Different swabs require different methods of use; proceed accordingly.<br \/>\n3. Click \u201cDetection\u201d Test results will be available in 15 seconds. (Manually save results.)<\/p>\n<h2>Test results<\/h2>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_92735293\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1820\" height=\"426\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results.webp 1820w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results-300x70.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results-1024x240.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results-768x180.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results-1536x360.webp 1536w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Bacteria-Detection-Steps-Test-results-600x140.webp 600w\" sizes=\"auto, (max-width: 1820px) 100vw, 1820px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_92735293 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<p><strong><span style=\"font-size: 130%\">Note:<\/span><\/strong>Take \u201cWater Testing \u2013 Drinking Water\u201d as an example.Qualified line \u2264 10RLU, warning line &gt; 10RLU and \u2264 50RLU.<\/p>\n<table style=\"font-size: 14.4px\">\n<tbody>\n<tr>\n<td>notation<\/td>\n<td>notation interpretation<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 115%\">&#8220;OK&#8221;<\/span><\/td>\n<td>Detection data \u2264 lower limit value<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 115%\">&#8220;!&#8221;<\/span><\/td>\n<td>Detection data\u2265lower limit value \u2264 upper limit value<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-size: 115%\">&#8220;-&#8220;<\/span><\/td>\n<td>Detection data&gt;upper limit value<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to upload data to PC?<\/h2>\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1902322649\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"588\" height=\"122\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Host-computer-software-operation.webp\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Host-computer-software-operation.webp 588w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/Host-computer-software-operation-300x62.webp 300w\" sizes=\"auto, (max-width: 588px) 100vw, 588px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1902322649 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n<p>1. Install the host computer software: copy the host computer software installer in the U disk to the computer, double-click the installation file, and follow the prompts to complete the software installation. If the installer cannot run automatically, please open the U disk folder and run the installer manually.<br \/>\n2. Connect the data cable: Use the data cable that comes with the instrument, insert one end into the miniUSB interface of the ATP fluorescence detector, and connect the other end to the USB port of the computer.<br \/>\n3. Open the host computer software: From the \u201cStart\u201d menu or desktop shortcut of the computer, find and open the installed ATP fluorescence detector host computer software.<br \/>\n5. Select the communication serial port: Click the inverted triangle on the right side of the communication serial port to select the serial port connected to the device.<br \/>\n6. Click Query: Query the historical data of the device.<br \/>\n7. Click \u201cExcel Export\u201d to export data: the export format is \u201cExcel\u201d format.<\/p>\n<div class=\"video video-fit mb\" style=\"padding-top:56.25%;\"><p><iframe loading=\"lazy\" title=\"ATP Fluorescence Detector\" width=\"1020\" height=\"574\" src=\"https:\/\/www.youtube.com\/embed\/rxWxGxPkw2w?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<\/div>\n<h2>Packing List<\/h2>\n<div class=\"row row-small\"  id=\"row-590557486\">\n\n\t<div id=\"col-2045725912\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Host.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Host.webp 400w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Host-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Host-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Host-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>ATP Fluorescence Detector<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1894318397\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab.webp 1600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-600x600.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1024x1024.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-150x150.webp 150w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-768x768.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-swab-1536x1536.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>Swab<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-327657100\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-1.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-1.webp 400w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-1-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-1-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-Aluminum-Box-1-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>Aluminum Box<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row row-small\"  id=\"row-1513156072\">\n\n\t<div id=\"col-819584170\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-1.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-1.webp 400w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-1-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-1-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-USB-flash-drive-1-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>USB Flash Drive<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-474100785\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-data-cable.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-data-cable.webp 400w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-data-cable-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-data-cable-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-data-cable-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>Data Cable<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1548921145\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" >\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head.webp 1600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-100x100.webp 100w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-600x600.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-1024x1024.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-150x150.webp 150w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-768x768.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/08\/ATP-Fluorescence-Detector-charging-head-1536x1536.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h4>Charging Head<\/h4>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<h2>Accessories Available for Purchase<\/h2>\n<div class=\"row\"  id=\"row-3072816\">\n\n\t<div id=\"col-1115249068\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:80%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1600\" src=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image.webp\" class=\"attachment- size-\" alt=\"\" srcset=\"https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image.webp 1600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-300x300.webp 300w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-1024x1024.webp 1024w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-150x150.webp 150w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-768x768.webp 768w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-1536x1536.webp 1536w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-600x600.webp 600w, https:\/\/tavnu.com\/wp-content\/uploads\/2025\/09\/ATP-Special-Swab-major-image-100x100.webp 100w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n<h3>ATP Special Swab<\/h3>\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-366085907\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>The ATP fluorescence detection swab is a dedicated companion tool for ATP fluorescence detectors, integrating sample collection, ATP cleavage, and reaction in one device, eliminating the need for additional reagent preparation. Its advanced liquid-based stable reagent is ready for use and prevents uneven dissolution, minimizing impurity interference, improving detection accuracy, and ensuring data reproducibility. Available swabs are compatible with both solid and water samples, facilitating rapid health screening in a variety of scenarios.<\/p>\n<a href=\"https:\/\/tavnu.com\/mac\/atp-special-swab\" class=\"button primary\" >\n\t\t<span>Go to purchase\uff01<\/span>\n\t<i class=\"icon-shopping-bag\" aria-hidden=\"true\"><\/i><\/a>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-891701200\">\n\n\t<div id=\"col-1679280124\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<ul class=\"sidebar-wrapper ul-reset\"><div id=\"text-2\" class=\"col pb-0 widget widget_text\"><span class=\"widget-title\">CONTACT<\/span><div class=\"is-divider small\"><\/div>\t\t\t<div class=\"textwidget\"><p>phone: +1 \u202a402 915 1622\u202c<\/p>\n<p>Email:<a href=\"mailto:hi@tavnu.com\"><span dir=\"auto\">hi@tavnu.com<\/span><\/a><\/p>\n<p>Address: 12 E Twohig Ave #200-F12, San Angelo, TX 76903, USA<\/p>\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f8-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"8\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct%2F66#wpcf7-f8-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"8\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.6\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f8-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_wpcf7_recaptcha_response\" value=\"\" \/>\n<\/fieldset>\n<p><label> Your Name (required)<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span> <\/label><br \/>\n<label> Your Email (required)<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span> <\/label><br \/>\n<label> Your Phone<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-tel\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-text wpcf7-validates-as-tel\" aria-invalid=\"false\" value=\"\" type=\"tel\" name=\"your-tel\" \/><\/span> <\/label><br \/>\n<label> Your Message<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\"><\/textarea><\/span> <\/label><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send\" \/>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n<\/div>\n\t\t<\/div><\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2134241952\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<ul class=\"sidebar-wrapper ul-reset\"><div id=\"nav_menu-2\" class=\"col pb-0 widget widget_nav_menu\"><span class=\"widget-title\">POLICY<\/span><div class=\"is-divider small\"><\/div><div class=\"menu-policy-container\"><ul id=\"menu-policy\" class=\"menu\"><li id=\"menu-item-135\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-135\"><a href=\"https:\/\/tavnu.com\/?page_id=81\">Cookies Policy<\/a><\/li>\n<li id=\"menu-item-134\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-134\"><a href=\"https:\/\/tavnu.com\/?page_id=83\">Disclaimer<\/a><\/li>\n<li id=\"menu-item-136\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-privacy-policy menu-item-136\"><a rel=\"privacy-policy\" href=\"https:\/\/tavnu.com\/?page_id=3\">Privacy Policy<\/a><\/li>\n<li id=\"menu-item-137\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-137\"><a href=\"https:\/\/tavnu.com\/?page_id=91\">Payment Method Terms<\/a><\/li>\n<li id=\"menu-item-138\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-138\"><a href=\"https:\/\/tavnu.com\/?page_id=14\">Refund and Returns Policy<\/a><\/li>\n<li id=\"menu-item-139\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-139\"><a href=\"https:\/\/tavnu.com\/?page_id=94\">Shipping and Delivery Policy<\/a><\/li>\n<li id=\"menu-item-140\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-140\"><a href=\"https:\/\/tavnu.com\/?page_id=96\">Terms and Conditions<\/a><\/li>\n<\/ul><\/div><\/div><div id=\"nav_menu-3\" class=\"col pb-0 widget widget_nav_menu\"><span class=\"widget-title\">SUPPORT<\/span><div class=\"is-divider small\"><\/div><div class=\"menu-support-container\"><ul id=\"menu-support\" class=\"menu\"><li id=\"menu-item-144\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-144\"><a href=\"https:\/\/tavnu.com\/?page_id=69\">ABOUT<\/a><\/li>\n<li id=\"menu-item-143\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-143\"><a href=\"https:\/\/tavnu.com\/?page_id=79\">Contact<\/a><\/li>\n<li id=\"menu-item-142\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-142\"><a href=\"https:\/\/tavnu.com\/?page_id=85\">FAQ<\/a><\/li>\n<li id=\"menu-item-141\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-141\"><a href=\"https:\/\/tavnu.com\/?page_id=89\">Order Tracking<\/a><\/li>\n<li id=\"menu-item-145\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-145\"><a href=\"https:\/\/tavnu.com\/?page_id=10\">Products<\/a><\/li>\n<\/ul><\/div><\/div><\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>As a professional manufacturer of ATP fluorescence detectors, we understand the core requirements of &#8220;fast, accurate, and convenient&#8221; for sanitary testing. This device can accurately capture microorganisms and biological residues in samples, providing on-site results in 15 seconds without waiting for laboratory reports. Its compact and portable size makes \u00a0it easy to transport to inspection sites. The high-definition touch screen makes it easy to use, and it also supports 12 hours of continuous testing to batch testing requirements. Whether it&#8217;s market supervision and law enforcement, food industry quality control, hospital disinfection inspections, or workshop cleanliness control, it saves time and ensures accurate sanitary testing!<\/p>\n<p>If needed, you can purchase spare swabs:<br \/>\n<a href=\"https:\/\/tavnu.com\/mac\/atp-special-swab\">Click here to purchase spare swabs<\/a><\/p>\n","protected":false},"featured_media":72,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[15],"product_tag":[],"class_list":["post-66","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/tavnu.com\/index.php?rest_route=\/wp\/v2\/product\/66","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tavnu.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tavnu.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tavnu.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=66"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tavnu.com\/index.php?rest_route=\/wp\/v2\/media\/72"}],"wp:attachment":[{"href":"https:\/\/tavnu.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=66"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tavnu.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=66"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tavnu.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=66"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tavnu.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=66"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}